Back to case studies
Chilled Food Environmental Monitoring
A6.EnvironmentChilled food storage

Chilled Food Environmental Monitoring

Find the record by cabinet and date in one place.

Case ID
EIA-03
Module
A6.Environment
Application
Chilled food storage
Industry
Food cold-storage warehouse
  • Chilled food
  • Quality
  • Alerts
SHEET 01 · Case story

Find the record by cabinet and date in one place.

The food cold-storage warehouse brings temperature/humidity, events and reports together. Quality and facilities staff can look up historical records by cold-storage area and equipment to trace environmental conditions.

SHEET 02 · Challenge and response

From the site problem to a system approach.

  1. 01The challenge

    Chilled-food sites need environmental trends and alert records, but information can be scattered and difficult to trace.

  2. 02The system approach

    Create cold-chain and environmental dashboard views that bring temperature/humidity, events and reports together.

  3. 03Reported outcome

    Let quality and facilities teams use the same records to track environmental conditions.

SHEET 03 · Architecture

System architecture and data flow.

Site-sensor data enters the existing platform, which presents views by cold-storage area, equipment and alert threshold. Source diagrams retain some original Traditional Chinese labels.

L4應用層Application
L3 → L4:REST API · WebSocket · LINE Webhook
L3雲端層Cloud
L2 → L3:TCP/IP over HTTPS
L2邊緣層Edge
L1 → L2:Modbus TCP / MQTT / API
L1感測層Sensing
Data flows upward
    • EHS Dashboard
    • 告警推播
    • 稽核報表
    • 行動瀏覽
    • CaseRecords by area and equipment
    • Environment Dashboard
    • Threshold Alerts
    • Site Management
    • Event Log
    • Audit Reports
    • CaseEvents and reports together
    • EIA Gateway
    • 既有平台 Box
    • 本地資料暫存
    • 溫濕度 / IAQ
    • 冷鏈 / 倉儲
    • 匯流排 / 熱點
    • 巡檢 / 事件
    • CaseCold-storage temperature/humidity
SHEET 04 · Wiring and hardware

Wiring diagrams and hardware configuration.

The diagram outlines data flow between site signals, edge devices, the network and the platform. Confirm installation and connection scope before work begins.

Original diagram notes (Traditional Chinese)
  1. 01主機櫃 / Main equipment cabinet 內含 24VDC PSU、既有平台 Box、EIA Gateway
  2. 0224VDC PSU(100~240VAC, 單相 / DC 24V / 5A / 工業電源)以 24VDC 紅虛線供電給 既有平台 Box 與 EIA Gateway
  3. 03既有平台 Box(IPC / HMI / Switch、本地資料整理、斷網本地暫存)與 EIA Gateway(RS485 / Modbus / Sensor、環境點位採集)以 Modbus TCP / MQTT 藍線連接
  4. 04既有平台 Box 上行至 既有平台 Cloud(部署於雲端 / 台灣):TCP/IP over HTTPS via customer LAN(綠線)
  5. 054× 現場訊號 / 表計 / 感測器資料以橙線接入 EIA Gateway:站點 A(溫濕度 / IAQ,RS485);站點 B(冷鏈 / 倉儲,Modbus);站點 C(匯流排溫度,Sensor);站點 D(巡檢 / 事件,人工輸入)

TOTAL既有平台 Box + EIA Gateway + 現場點位 / 表計 / 感測器 = EIA 基準配置

Original diagram legend藍線 = Ethernet / Modbus TCP / TCP-IP;綠線 = HTTPS / TCP-IP (Cloud Uplink);橙線 = 溫濕度 / IAQ / 冷鏈 / 熱風險點位資料;紅虛線 = 24VDC Power / 低壓電源Planning reference with Traditional Chinese labels. Confirm wire colors, terminals, power and communications against site-approved documents.
SHEET 05 · Before implementation

What to confirm before work begins.

This material describes a planning direction. Confirm site points, installation, report definitions and alert rules against actual site conditions.

  1. 01Site points and signal sources
  2. 02Communication protocols and network conditions
  3. 03Power, panels and installation method
  4. 04Report fields and data definitions
  5. 05Alert rules and responsible people
  6. 06Equipment brands, models and quantities

END · Next step

What would you most like to solve on site?

An equipment list, a panel photo or a problem you face every day is enough to start.

  1. 01An equipment list
  2. 02A panel photo
  3. 03A problem you face every day