Use trends to find where electrical equipment is heating up.
The textile plant uses thermal sensors and edge equipment to record electrical hotspots and create threshold alerts and event records. The data supports preventive management; fire response still follows applicable professional standards.
From the site problem to a system approach.
- 01The challenge
Without continuous data, electrical-equipment heat anomalies may only be investigated after the fact.
- 02The system approach
Use thermal sensing, threshold alerts, event records and trend tracking to support preventive management.
- 03Reported outcome
Give thermal-risk management records to review instead of relying only on paper inspection sheets.
System architecture and data flow.
Thermal sensors and edge equipment form a monitoring network; the existing platform handles events, alerts and reports. Source diagrams retain some original Traditional Chinese labels.
- EHS Dashboard
- 告警推播
- 稽核報表
- 行動瀏覽
- EHS Dashboard環境總覽 · 異常站點
- 告警推播Email / LINE · 責任人通知
- 稽核報表歷史趨勢 · 追溯下載
- 行動瀏覽主管手機 · 即時查看
REST API · WebSocket · LINE Webhook- Environment Dashboard
- Threshold Alerts
- Site Management
- Event Log
- Audit Reports
- CaseThreshold alerts and event records
- Environment Dashboard溫濕度 / IAQ · 即時總覽
- Threshold Alerts門檻告警 · 分級通知
- Site Management站點 / 設備 · 點位管理
- Event Log事件履歷 · 追溯資料
- Audit Reports稽核 / 追溯 · 報表匯出
- Case signalThreshold alerts and event recordsSource|Case story:The textile plant uses thermal sensors and edge equipment to record electrical hotspots and create threshold alerts and event records. The data supports preventive management; fire response still follows applicable professional standards.
TCP/IP over HTTPS- EIA Gateway
- 既有平台 Box
- 本地資料暫存
- CaseThermal sensors and edge equipment
- EIA GatewayRS485 / Modbus · 感測器接入
- 既有平台 Box站點與設備對應 · 資料整理
- 本地資料暫存斷網補傳 · 事件不遺失
- Case signalThermal sensors and edge equipmentSource|Case story:The textile plant uses thermal sensors and edge equipment to record electrical hotspots and create threshold alerts and event records. The data supports preventive management; fire response still follows applicable professional standards.
Modbus TCP / MQTT / API- 溫濕度 / IAQ
- 冷鏈 / 倉儲
- 匯流排 / 熱點
- 巡檢 / 事件
- CaseElectrical hotspots
- 溫濕度 / IAQ環境品質 · 站點監測
- 冷鏈 / 倉儲冷藏設備 · 溫度趨勢
- 匯流排 / 熱點熱風險 · 溫度點位
- 巡檢 / 事件人工紀錄 · 異常事件
- Case signalElectrical hotspotsSource|Case story:The textile plant uses thermal sensors and edge equipment to record electrical hotspots and create threshold alerts and event records. The data supports preventive management; fire response still follows applicable professional standards.
Wiring diagrams and hardware configuration.
The diagram outlines data flow between site signals, edge devices, the network and the platform. Confirm installation and connection scope before work begins.
Original diagram notes (Traditional Chinese)
- 01主機櫃 / Main equipment cabinet 內含 24VDC PSU、既有平台 Box、EIA Gateway
- 0224VDC PSU(100~240VAC, 單相 / DC 24V / 5A / 工業電源)以 24VDC 紅虛線供電給 既有平台 Box 與 EIA Gateway
- 03既有平台 Box(IPC / HMI / Switch、本地資料整理、斷網本地暫存)與 EIA Gateway(RS485 / Modbus / Sensor、環境點位採集)以 Modbus TCP / MQTT 藍線連接
- 04既有平台 Box 上行至 既有平台 Cloud(部署於雲端 / 台灣):TCP/IP over HTTPS via customer LAN(綠線)
- 054× 現場訊號 / 表計 / 感測器資料以橙線接入 EIA Gateway:站點 A(溫濕度 / IAQ,RS485);站點 B(冷鏈 / 倉儲,Modbus);站點 C(匯流排溫度,Sensor);站點 D(巡檢 / 事件,人工輸入)
TOTAL既有平台 Box + EIA Gateway + 現場點位 / 表計 / 感測器 = EIA 基準配置
Sensors, PLCs, edge gateways and communication modules are selected around the equipment already available at the site.
Original diagram notes (Traditional Chinese)
- HW-01現場訊號來源設備 / 表計 / 感測器;狀態、數值、事件
- HW-02EIA Gateway接收現場訊號;轉換通訊資料
- HW-03既有平台 Box本地資料整理;斷網暫存 / 上傳
- HW-0424VDC PSU工業電源;低壓供電
- HW-05既有平台 CloudDashboard / 告警 / 報表;角色權限與資料庫
What to confirm before work begins.
This material describes a planning direction. Confirm site points, installation, report definitions and alert rules against actual site conditions.
- 01Site points and signal sources
- 02Communication protocols and network conditions
- 03Power, panels and installation method
- 04Report fields and data definitions
- 05Alert rules and responsible people
- 06Equipment brands, models and quantities
END · Next step
What would you most like to solve on site?
An equipment list, a panel photo or a problem you face every day is enough to start.
- 01An equipment list
- 02A panel photo
- 03A problem you face every day